* Disclaimer: OveReview is reader-supported. We earn commissions from qualifying purchases
Siemens W0408ML1125U Load Center, Gray

Siemens W0408ML1125U Load Center, Gray

Siemens W0408ML1125U Load Center, Gray
$ 38.20

Score By Feature

Based on 186 ratings
Durability
9.73
Heat resistance
9.30
Easy to clean
8.89

OveReview Final Score

How Our Score Is Calculated

Product Description

There are six items in this weight category. The weight of eight pounds
China is the country of origin
The Siemens brand is a well-known one
The item measures 13 inches long, 13.5 inches wide, and 8 inches tall. A crow's foot measuring 0" long by 7" wide. This is a 0"W x 5"H sheet. The zero inch

Questions & Answers

Does this need a ground bar isolated from the rest of the design?

This unit can be field configured to operate at either ECGB5 or ECGB10. Despite the fact that they are not insulated, these ground bars are still useful.

Would it be possible to run a qf260a circuitbreaker and a q3020 circuitbreaker on the same circuit?

I would say yes to that question. Hire an electrician who is licensed to do the job. Ensures the satisfaction of the fire insurance companies!

The 3-wire connector nema 6 can be used as a receptacle There are 4 wires (neutral) for nema 14-type receptacles as well as 50r ?

Yes, the ground bar might need to be added.

Selected User Reviews For Siemens W0408ML1125U Load Center, Gray

Using these tips, I was able to solve some of the issues I faced
4/5

Specific to the panel model W0408ML1125U, this review has been written. Several of the other models that show up are probably for another model. In order to install the inner panel, you must first remove it from As it took me a great deal of time and effort to twist and pull everything out, I hope this will make the process easier for you. By lifting the bottom of the panel, you can make it higher than the screw terminal which is at the bottom, then tapping the top with a hammer through the big hole in the top. As soon as I did that, it came right out. As such, the hub hole cover can now be placed on top if you so desire. You are in charge of your own life The process of threading a nut can be a bit tricky, but if you rotate slowly and press as you turn, it should work fine. We urge you to note that this box does not include Regardless of the application, if this is to be used as a subpanel or disconnect, you will need to include a ground bar to ensure the box and ground for each input and output are tied together separately from the neutral. The form factor of this small box makes it impossible to use as the Including the ground bar is a good idea. The ECGB14 bus ( ) is said to be appropriate for this box in some reviews. I don't think it is. Due to the absence of mounting holes that work with the self-adhesive ground bus, this box does not have a right ground bus. The screws that came with it needed to be tapped. To be fair, there is one hole covered with a sticker that might be right for some ground bus or another, but it was too big for the screws that came with it. I used my drill press to drill holes where I wanted them, so it was not difficult. The situation may not be as fortunate for you. Across the top of the spa box, I used a QF260A GFCI breaker ( ). As far as code requirements are concerned, it meets them. On Amazon, there's a Siemens unit with a 60A GFCI breaker, but it's unclear whether the breaker is this newer one or the older Q260, which doesn't have the built-in safety device. You might want to test certain One of the reasons I ended up developing my own was because of this issue. Besides these two auxiliary circuit slots, this box gives me the option to connect auxiliary circuits if needed (as long as I provide the proper wires from my panel to feed it). The screw in the neutral bus grounding kit makes it easy to fix the inner panel because it fits the bottom part of the kit with a large head. Due to its self-contained nature, it may be hard for you to get started The threading process. Before using this, your neutral bus should be grounded. If you aren't sure whether this is the case, speak with an electrician.

Lyla Sandoval
Lyla Sandoval
| Jan 31, 2021
This is a good product
5/5

purchased this box so that I could replace an old hot tub subpanel (of an identical model) that the previous owner had ripped apart I have power in my shed now and it is working great so far. In addition to others having mentioned it doesn't come with a ground bar, which is a bit odd, but you can pick one up at Home Depot (any brand) for just a few bucks and attach it.

Luca Burgess
Luca Burgess
| Apr 16, 2021
The film is pretty good, but there are better films
4/5

The 2 pole subwoofer would be suitable for a little 2 full size 2 pole breaker In terms of the panel, it works pretty well. A thin wing nut secures the thin plastic pin that holds the top cover in place by creating its own thread and is a pretty wimpy clamp. A ground from the sub-bus or even a lug will have to be obtained because there is no ground there. You can't use the neutral bus for ground. A panel. It is a narrow box, so it will be more difficult to locate the ground bus and wire. A plastic pin with a one-way locking washer holds the bus bar in place. However, it works with a little bit of jiggling. There's a bit of a struggle to remove and reinstall the cover. It is the Siemens 240V 2 pole GFCI breakers I like and the reason for my purchase of this spa panel.

Luka PARKIN
Luka PARKIN
| Jan 29, 2021
There's some genius who decided it was a good idea to mount the breaker box against the A/C unit
4/5

It seems that my breaker for the air conditioning went An air conditioner housing is situated against the breaker box because some genius thought it would be good idea. We replaced the breaker box with a replacement one because the shakes of the old one loosen the breakers. Although everything fits well, there are some problems with the sealing of the openings.

Foster Moss
Foster Moss
| Aug 25, 2020
The price is fair, but it does not have a
5/5
Queen Tyler
Queen Tyler
| Jan 08, 2021
The product is durable
5/5

It is of great quality.

Rhett Parsons
Rhett Parsons
| Jul 09, 2021
I love it!
5/5

I'm in love with.

Zayden Strong
Zayden Strong
| Feb 17, 2021
The project worked fine, but it did not include a ground bar
5/5

The project worked fine, but it did not include a ground bar.

Major Randolph
Major Randolph
| Mar 05, 2021

Related Products For Siemens W0408ML1125U Load Center, Gray