* Disclaimer: OveReview is reader-supported. We earn commissions from qualifying purchases
Quadrafire Thermocouple 812-0210 800/1000/1100i/1200 Quadrafire Thermocouple 812-0210 800/1000/1100i/1200 Quadrafire Thermocouple 812-0210 800/1000/1100i/1200

Quadrafire Thermocouple 812-0210 800/1000/1100i/1200

Quadrafire Thermocouple 812-0210 800/1000/1100i/1200 Quadrafire Thermocouple 812-0210 800/1000/1100i/1200 Quadrafire Thermocouple 812-0210 800/1000/1100i/1200
$ 36.99

Score By Feature

Based on 217 ratings
Delivery
8.83
Value for money
8.49
Giftable
8.45
Satisfaction
8.84

OveReview Final Score

How Our Score Is Calculated

Product Description

By entering your model number, you can make sure that this fits.
QuadraFire Thermocouple Pellet Stoves 800, 1000, 1100i, 1200, 1200i 812-0210
Original Equipment Manufacturer (OEM), Fastest Shipping, and Lifetime Technical Support!
Thermocouple Replacement in the Most Recent Style
Shipping is completely free.

Questions & Answers

Is it possible to get one as soon as possible?

In most cases, we ship within 24 hours of receiving your order and use USPS Priority Mail. In most cases, two Three days for business.

Is this compatible with the quadra-system? cb1200-fire ?

Hello - Yes, this would work on a classic bay 1200. Thank you so much, Nathan! esstoves are a type of stove that is used to cook food.

What is the best way to put a thermocouple in place?

Installing the thermocouple is actually quite simple; simply reverse the process of removing the old one, but take careful note of where the two electrical connectors' specific screws are located. You'll feed the thermocouple's head into the firepit area from the back of the stove, fasten it to the bracket, and cover it with the ceramic head cover so it juts over the actual fire pit. You must have the ceramic cover, so get one if you don't already have one and make sure it stays on the thermocouple's twisted head at the bracket. Then simply secure the two electrical connectors in their proper locations in the back, and you're finished!

Selected User Reviews For Quadrafire Thermocouple 812-0210 800/1000/1100i/1200

Color-coded wires for thermocouples are incorrect
3/5

I'm a service technician, and I purchased three thermocouples. They are compatible with the Quadra- 1100I, 800, 1000, 1200, 1300, 1400, 1400, 1400, 1400, 1400, 1400 1200I. When I first tried it on a 1200I, it didn't work. So I switched the wires around and discovered that the red and yellow coatings had been reversed when they were assembled. These wire connections are polarity aware, and the unit functions properly. Two metals are used to make the thermocouple. If it doesn't work, try switching the wires before returning it.

Kinslee Cortez
Kinslee Cortez
| Jun 24, 2021
Color code Yellow Red is something to look into
5/5

The thermocouple performed admirably. However, keep in mind the polarity of the wires. The red wire goes to the back of the control box, according to my manual, and the old one had yellow left and red right as well. I checked MilliVolt and the probe was working, but the polarity was reversed, so the heater did not work and shut down. On the terminal strip, I switched the yellow and red. It appeared to be successful.

Rodney Finley
Rodney Finley
| Dec 16, 2021
Bought for a quadrafire freestanding classic bay pellet stove, but was not the correct part, despite the fact that the part on the bag was correct
3/5

I immediately noticed that the wire was of a much lighter gauge than the original, and that the ends were not twisted, but simply soldered. I assumed it was the new replacement because the part was correct, so I installed it with a new fire pot gasket, thermocouple mount, and a few other things, and when I tried to fire it up, it would start the initial fire but then stop feeding pellets, leaving me perplexed. After visiting a local stove shop, I discovered that the thermocouple I had was not the right one for my stove because it is much heavier, has twisted and soldered ends, and is much heavier. After a week and a half of trying to figure out what was still wrong, I purchased and installed one from a local shop. Since then, the stove has been operating properly thanks to the thermocouple. After explaining the situation to the seller, I had no trouble getting a refund. Thank you very much.

Amayah Diaz
Amayah Diaz
| Sep 20, 2021
The product does not match the image and is not the same as the OEM
3/5

Although this thermocouple is not identical to the OEM, I believe it may be your only option. Note that yellow (on OEM) equals red (on this thermocouple) and red (on OEM) equals green (on this thermocouple) if you buy this. If you install your stove in reverse, it will go through the startup process but will not require pellets once it has warmed up. Also, because this is a shoddy product, double-check that all of the clips are securely fastened to the wires before proceeding.

Melanie Landry
Melanie Landry
| Aug 24, 2021
Everything is in order
5/5

I reinstalled my Quadrafire after picking it up from our local dealer after it had been cleaned and a part replaced, not knowing any better, and it worked fine for about two years, until it stopped working properly due to the pellet stove's infrequent use. After some investigation, I discovered that the thermocouple cover had been removed, causing the thermocouple to burn. No one is to blame, but make sure the ceramic cover is in place at all times. This thermocouple, as well as the cover, were purchased, and everything works fine. When buying this piece, make sure to get the less expensive cover, which is identical to the one I had before. The Quadrafire 800 is the model I have, and it fits three or four different models.

Janiyah Becker
Janiyah Becker
| Jun 02, 2021
it was a success I initially installed it with the polarity reversed, as per previous reviews' recommendations
5/5

The unit would turn on but not feed after the first fire; I changed the polarity to the original specification and it worked perfectly. I saved $90. 00 if you compare it to the dealer's price. Excellent value for money.

Milana Noble
Milana Noble
| Jan 02, 2021
Buy NOTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT If you have a Quadra-Core processor, you should not buy this
3/5

Classic Bay 1200 is a fire pit. The connectors on this item are much smaller and do not seat properly. My control board went bad as a result of this thermocouple, which cost me $220. I purchased a genuine thermocouple from my dealer, and it worked perfectly with the new control board. This was a huge mistake. I've attached a photograph.

Kimora Proctor
Kimora Proctor
| Jul 22, 2021
The device was not functional
3/5

For some reason, the thermocouple failed to work. As a result, I had to purchase one locally in order to get my stove to work.

Trace Conrad
Trace Conrad
| Aug 10, 2021