Square D by Schneider Electric HOMT2020250CP Circuit Breaker, Black
Score By Feature
OveReview Final Score
Product Description
Questions & Answers
My search led to the 30/3050 the 30 amps are on the outside and they provide 120 v and the 50 amps are on the inside and they provide 220 v I don't have it listed but you can go ahead and get this 3050 instead of the other one.
breakers are connected together for a common trip and each one is rated for 50 amps. There are two 20 amp breakers, one single pole and one double pole This isn't a connected set of programs & One trip can be taken independently of the other.
The HOMT2020250 breakers were not tested for use in Challenger panels, and therefore only need to be used in Homeline panels.
Selected User Reviews For Square D by Schneider Electric HOMT2020250CP Circuit Breaker, Black
This is a question I would like to ask everyone. It seems like though a home center is offering good deals, it sounds like Gnome Rip-Off. Is it Off or perhaps Gnome Repo' that sells the same item for more than The margins they operate on, what are they? The shipping will be free to my residence and the cost will be $20. It is hard to believe that this could be true. Except for that, it is a circuit breaker, and there is no big review fanfare to celebrate, though! The magic pixie outlet works as it should to keep the lights on, and if little Billy shoves a metal dohicky object into the outlet, the power will cut like it should just before the joint burns.
There are some "cheater breakers" here, and I expect more people to be aware of this before purchasing it. Therefore, it may need to be modified to fit in your breaker box in some positions. In my case, this is what happened. My hot tub needs a 50A 220V circuit, so after I customized it, the circuit snapped into place, allowing me to retain my two 20A circuits and add the 50A circuit. The overall amperage usage needs to be taken into account in order to install this type of the adjacent 20A circuits on my house don't consume much power, even though they are connected tightly together.
Even though I only needed the 50A breaker, I decided to test it out and ended up using both of the 20A breakers. I was able to attach wires in a normal, forgettable way with it by snapping it into the Square D Homeline panel.
My Tesla charger was wired with this to put in a Breaker. For the garage outlets, I needed to keep my 220V breaker group together, but I wanted to put it immediately below my stove breaker so that I would not have to pair the two circuits together. This puppy works like a champ! I plugged everything in, and it worked right away. Due to the holes being smaller than the standard breaker, you may want to use the thin blade flat. Install this only if you know everything about your home's electrical system. If you don't, you could seriously harm yourself or burn down your house!.
The pick of 20 and 50 amperes is the same as the pick of double 20 and 2-amperes This 20 amp combo was not found in the library. It will fit after the plastic slot where the breaker slips over the hot bar has been elongated. The engineering on this is terrible! All that needs to be done is field engineering.
That's a pretty cool concept. You just have to make sure you get a Square D Homeline panel when you buy it. I really like the fact that it goes in with great precision (at least on my set up), so last but not least I would say that it goes in snugly. In other words, I want to know we've got a nice, tight connection.
I noticed there was one wrong set screw on the breaker that was obviously not One of the 20 amp switches will not reset because it is defective. We hope to return soon!.
This type of breaker can save you a ton of money because you do not have to replace the whole panel just to add a new breaker as you have to do when you add a heat pump. I was able to add it to my Homeline panel without any problems.