* Disclaimer: OveReview is reader-supported. We earn commissions from qualifying purchases
Square D by Schneider Electric FSG2J24CP 40-60 PSI Pumptrol Water Pressure Switch, Grey Cover

Square D by Schneider Electric FSG2J24CP 40-60 PSI Pumptrol Water Pressure Switch, Grey Cover

Square D by Schneider Electric FSG2J24CP 40-60 PSI Pumptrol Water Pressure Switch, Grey Cover
$ 19.82

Score By Feature

Based on 864 ratings
Easy to install
9.70
Accuracy
9.70
Value for money
9.48

OveReview Final Score

How Our Score Is Calculated

Product Description

The Pumptrol (TM) Water Pressure Switch works at pressures ranging from 40 to 60 PSI
Pumps such as jet pumps, submersible pumps, and reciprocating pumps can be used
A new round of standard-action contacts is opened after
The pressure should range between 40 and
A quarter of an inch. Connection between pressure and pressure

Questions & Answers

The Square D Pressure Switch FSG2J24CP I have is from Square D. The following is updated every 30 minutes The faucet does not go off even without a leak or even when there is no water used. Is that normal?

The norm is definitely not the norm. Probably a small leak somewhere in a faucet, toilet, or other fixture is to blame. You should also make sure that the threads are well sealed at the switch (teflon tape). Besides the rubber diaphragm, the switch also has a small replaceable diaphragm that may develop a pinhole leak and cause a very slow pressure loss, which influences In the past, I must have had a similar issue when I replaced this switch. However, I found that it actually had to do with the crack in the 30 year old plastic on the well pipe. Do not give up There will be a solution to the problem at some point.

Hello, I have now this kind of switch and I am thinking about replacing it. Does this switch need to be bought Have you seen the switch made by this company, the one that uses one nut to adjust it? Would that be alright with you?

It is best to purchase a switch that is the same or very similar to what you have now. There are many types of switches with different internal constructions. Two terminal lugs are usually visible on the body of the switch.

The cover only seems to be held on by this nut at the top? It's better to be safe than sorry, right?

all there is to After you are done adjusting the fitting, tighten it up a bit, but not too tightly. Pull straight up the first time you take the cover off. Unscrew the nut a second time.

Do Square D 9013fsg2 and FSG2J24CP have the same part number?

This is not exactly the case. The talk is 20 minutes in length The FSG2J24CP is a 40-psi set while the FSG2J24CP is a 40-psi set This set has a pressure of 60 psi. The start and stop pressures on these machines are different but the mechanisms function the same. There may be an option up that high, but you shouldn't depend You may end up with an unacceptable output from your well if you replace it with it.

Selected User Reviews For Square D by Schneider Electric FSG2J24CP 40-60 PSI Pumptrol Water Pressure Switch, Grey Cover

This is an excellent replacement for the built-in switch on a pump
5/5

Solar power is the only source of energy in my house It's a grid cabin that I am building. I run my 24V DC battery bank to run my water pump. I was very disappointed when the pressure switch within the pump head failed after less than a year of use. This appears to be a common complaint with the pump, based on reviews. Schneider Electric Square D by FSG2J24CP 40-inch fluorescent tube came to my attention when I was shopping for this product At the recommendation of an electrician friend, I installed a Pumptrol 120 PSI pressure switch that provides a more reliable solution.

I had to install a tap from the output of the pump, into which I installed a Square D pressure switch. can say that the pump now starts and stops noticeably cleaner, so it has become obvious that the old pressure switch is The contacts in this Square D pressure switch are rated for Over eight amps is how much power my pump motor draws. It is expected that the new pressure switch will last for many years (as said by my electrician friend). * Before you find out that my installation is not NEC compliant, there is an emergency wiring from the valve to a future wall. Backing to my installation, the conduit from the pressure switch to the future wall is to ensure there is water in the cabin when needed. Fortunately, a conduit is on the way and will be delivered in a few days. Thanks for catching that!.

Rodrigo Conway
Rodrigo Conway
| Jul 27, 2020
Pressure switch on the market that works well
5/5

This is a very reliable source. It was the best pressure switch I found in my local hardware store. I found other similar switches, but none worked as well as the Square D. Please take note In the event that the bladder of your pressure tank is broken, you MUST replace this switch. The sediments from the well will fill the bottom of this switch and it will not function. Since I had to figure out this problem myself after replacing the tank for 3 hours, I would recommend always installing a new pressure switch when a tank needs to be replaced. In the same way, you will also want to work on the pressure gauge which may also be contaminated with sediment. In this case, I recommend purchasing a complete tank "TEE" kit when replacing the tank and it will save you a lot of time.

Justin Stafford
Justin Stafford
| May 12, 2021
Switches from Square D can't be beat
5/5

It is an old water pump I got when I installed a new water pump There is a comment in the pump reviews about the junky pressure switch that came with the pump. All the parts I needed to replace the pump and tank, including the pressure switch, were in the package. Using the pump was a time-consuming process, so I decided not to stop in the middle of it to run to the store. It is a good thing I did because when I hooked up the pump and turned it on, the pump wouldn't work. The pressure switch had failed. As soon as I replaced the switch, it started working. Switches from Square D can't be beat.

Leighton Koch
Leighton Koch
| Dec 07, 2020
Personally, I use this SquareD FSG2J24CP switch to achieve better pressure than stock (to match the PressureBooster WX-100) in conjunction with a WellXtrol WX5000 The reference number is 203
4/5

Please be aware that this unit does not come with a "trip" switch to kill the electrical feed to the pump in the event of a dry well. It will be necessary to include an external mechanism to prevent a well pump from overheating. Personally, I use this SquareD FSG2J24CP switch to achieve better pressure than stock (to match the PressureBooster WX-100) in conjunction with a WellXtrol WX5000 It also comes with a Pentek SPP-203 pressure tank The 233P - The pump cutoff switch acts as a pump protector. I found the Pentek unit to be quite handy or my irrigation system in the yard. Every once in a while, my shallow well will run too low and cut power. With this unit, the power will be cut off, but for a period of time, power will be restored. In the past, I had to manually reset the well before I could use the Pentek unit. A burned up yard or a house/pipe that freezes when the boiler has no water (in the winter) can be signs of this problem. When the problem has been resolved (in my case, the low water table), the Pentek will try to start the pump again.

Dylan O’SULLIVAN
Dylan O’SULLIVAN
| May 30, 2021
It is exactly what I need for my job! As a result of setting up a well on our property, I realized that I had to buy a pressure regulator to achieve my water system goals
5/5

In my research, I picked Schreider because I had heard good things about the brand. Despite its reputation, it lived up to it. This product is easy to install and adjust, as well as enduring. I can now just turn on the faucet, press the water pressure button and the pump will start automatically, maintain pressure, and shut off automatically when the faucet is closed. There is no better or simpler way to put it. It has been a great purchase for me.

Marlon Morse
Marlon Morse
| Aug 13, 2020
I urge you to read this
5/5

The same old things that have worked for decades A square that is tried-and-true A pressure difference of 2. 56 This switch has reliably operated in millions of sets and has done its job for years Everywhere you turn in this world, there are houses and basements. It is usually taken for granted until the water stops flowing. There is no good reason this switch needs to be located close to the well-being of the citizens There is no pump or pressure-producing device An engine The pump will perform its primary function as long as it is screwed into the water system anywhere convenient. I lived in a drafty poorly heated house for a year and a half. Having such a small water-system at your house can be frustrating A pressure line can be connected to it An initial component of a slush-process is a switch Water in smaller bodies of water will freeze solid longer before the larger body of water It even occurs to lines to freeze. As long as the switch is located in a warm area, this does not pose a problem. In order to make it reliable, the gauge should be visible in close proximity to the pressure-signal Change the channel. It is not unusual for a switch to function accordingly, even if nothing is wrong with the switch itself. However, debris can be found within that little pipe-nipple that screws into the switch, and this stops the water from flowing properly. Rather than having to evacuate the system, add a ball valve to minimize damage I suggest cutting- It is located on the off valve of the pressure-relief system It is connected to the system by a switch line In this case, it is possible to close the valve, screw off the switch, and clean the line of crud a brass-plated valve can be used for this task Fire a few rounds of the bristle shot and move on Taking care of this with a brush is a good idea. To terminate the HOT wire from the breaker rather than wire the switch directly to the stiff solid copper wires, connect the switch's CONNECT wire instead There is a box on the wall-- Plug receptacle, 220V or 110V, of the appropriate type. You will need a flexible stranded cable with the appropriate MALE connector to connect it to the switch's terminals by means of a ring-shaped connector A terminal. In addition to the flexible cord, a BOMLE plug on the switch side and a FEMALE plug on the well side would also be useful The pump side of the pressure switch takes care of the switched side Change the channel.
With such tools, it is quite easy to remove and dispose of Unplug the cords, making it safe to work on the switch, and then service / adjust the switch or unplug the device Remove it from the water and screw it in You can order on-line without the hassle of unpacking Installation of wiring and rewiring The stiff wires need to be wired. This is the switch that came with my new phone A pressure of 40/60 PSI should be used. Turn clockwise two full turns - Taking your time to read and study yielded 50/70 PSI.

Wallace Villanueva
Wallace Villanueva
| Apr 02, 2021

Related Products For Square D by Schneider Electric FSG2J24CP 40-60 PSI Pumptrol Water Pressure Switch, Grey Cover