Motor Starter 10hp 3ph 230V definite purpose magnetic motor starter from Square D 8911dpsg33v09
Score By Feature
OveReview Final Score
Questions & Answers
No, I don't think so. A raintite nema3r enclosure should be used. Check to see if it's big enough to accommodate the wiring.
On an enclosure, this is only the magnetic starter. A control signal (typically 120 volts) is required for the coil to work. However, 12Vdc or 24Vdc are possibilities. It is dependent on the coil specifications.) This particular panel does not have a control loop that allows it to start and stop automatically. Unless you specify a 120v coil and an on/off switch to control the 120vac to energize the coil (which can come from any regular wall outlet), closing the mechanical contacts and powering your equipment, that must come from somewhere else.
Is the area particularly dusty? What type of dust is it, and is it explosive or extremely flammable? If dust is a concern, an explosion-proof starter may or may not be required. Dust may not be an issue if it is to be used in a woodworking shop. The motor contactor is rated at 10 HP, and the overloads are also rated at 10 HP. If the motor you're going to use is smaller, you'll need to order the appropriate overloads to protect it.
The wiring diagram is nowhere to be found. Take your time finding the wiring from the contractor's line side to the coil, from the coil to the overloads at the bottom of the contractor, and back to one of the Line side contactor terminals. The coil receives 240 volts from this loop, which is protected against overload. The air compressor switch for starting and stopping can be inserted by opening the control loop anywhere. Connect one side of the switch to one terminal and the other side to the other terminal when you open the loop. The switch will be connected in a series configuration. Make sure you haven't shorted anything by tracing the wiring once more. Install the cover before turning on the computer. If the motor runs backwards, change two of the motor leads, assuming this is a three phase motor. Stand off to the side of the circuit breaker, shield your eyes, and energize. Note the direction the motor should spin (rotate) before energizing.
Selected User Reviews For Motor Starter 10hp 3ph 230V definite purpose magnetic motor starter from Square D 8911dpsg33v09
It worked perfectly and at a great price, so I'm very pleased with my purchase.
This is a single-phase or three-phase motor protection device. It's critical to understand the amps on the equipment or motor you're installing.
The item arrived as described, at a great price, and in a timely manner. The next day, my irrigation pump was up and running! Based on my personal experience, I would recommend this seller.
It's fantastic.
Yes, it was successful. It's a basic, no-frills starter. It hasn't tripped as of yet. The heaters are standard heaters, so they should work fine; alternatively, you can buy one for three times the price!.
work in the manner described.