Sealproof Power Whip Assembly, 1/2-Inch x 6 Ft Nonmetallic Liquid Tight Flexible Electrical Conduit and 10 Gauge Wire Single Phase Preassembled A/C Hook-up Whip Kit, 1/2"
Score By Feature
OveReview Final Score
Product Description
Questions & Answers
It is stranded, yes.
Yes, it was designed for a 30 amp circuit, so it will have plenty of juice to power a simple
One end has a female threaded end that receives the fiber end and is used to glue to rigid pvc conduit. A connector of this sort can be found from Carlon and Cantex.
You can cut the sealtight by taking one of the ends off and pulling the wire back until it is shortened enough to cut it, then replace the end and cut the wire to required length.
Selected User Reviews For Sealproof Power Whip Assembly, 1/2-Inch x 6 Ft Nonmetallic Liquid Tight Flexible Electrical Conduit and 10 Gauge Wire Single Phase Preassembled A/C Hook-up Whip Kit, 1/2"
It was a little difficult to install. This waterproof flexible conduit is exactly what I need to wire We found the price to be fair and the delivery to be quick. odd thing is that even though the junction is on the left, the part that inserts into it is one piece with the nut that attaches to the conduit. An angle fitting is a fitting with an angle. On my pump, where the nut has a threaded entry and requires a right-angle nut, this means the pump must be plugged in from the right side Because the entire cable must be rotated around a few times to insert a pump nut, the pump end has to be attached before the angle connection. In the next step, the conduit is cut to length and the nut is glued to the other end of the conduit. Furthermore, if you tighten the nut on the conduit too much, it won't unscrew, for example, if you want the conduit length changed. In more traditional conduits, the nuts would be separate from the portion of the conduit that mounts into the pump or junction box, so either end of it could be attached first. However, this whip was just as I needed it to be, and it got the job done.
The Seal looks like this Conduit cable assembly with 4-pin connectors made from tie type flexible conduit THHN wires of 10 gauge did the job very well and for a very reasonable price. This cable assembly can handle up to a 30 AMP load and is 6 feet long with sufficient extra 10 gauge wire to hook up from a circuit breaker sub-panel. An air conditioner panel should be connected to a connection point in the air conditioner. Wires are designed for 240 VAC hook-ups, but these cables can be used for other voltage levels as well It's a good purchase I can't find anything wrong with it. It is a pleasure to work with you.
My purpose for this is the same as others' to feed a hamster It has a split air conditioner This is a simple whip assembly, but it is made of high quality components, so you'll have everything The parts are all there, ready to go. There is no need to piece it all together from different places. Neither the conduit nor the connections at each end are arranged in a logical manner It is amazing how thin this is. The wires inside are stranded nicely, and there are plenty of them to wire up at each end without worrying about running out of wires. It is exactly what you expect when you order it.
I purchased it to install a mini split (30,000 BTU). Everything seems to be working fine. The length of the cord is adjusted to the size of the mini split unit (90 degrees) and the shut-off valves, both fitted onto the mini split unit Those in straight style (off switch box), are of solid construction. We purchased our wiring from a trusted vendor as well. The situation turned out to be smooth. As soon as I need it again, I will buy it. In case your existing bolt holes are larger than the fittings, it comes with a couple of 3/4" to 1/2" plates to adapt it.
The fittings consist of red, black, and ground) and a pair of red screws Neoprene O rings seal your neoprene hose in both directions one straight and one 90 degrees. In case of too much length, it can be trimmed. The product has been used for short-run exterior applications, such as air conditioning and generators. It's easier to use non-PVC than PVC A metallic tube and the fittings that go with it. If the wires need to be changed, replace them If you need to run wires through the 1/2-inch flex, you'll need a total of 4 THHN 12 ga wires. The quality of the product is excellent.
Because the wire is stranded, it is very flexible, making installation very easy. The 12000 BTU Mini Split Air Conditioner will work well with this unit.
The only issue was that it was a little bit long for me, which was by design. I wanted to ensure it was long enough for my use. In the past, I've bought stuff like this in pieces and forgot something, costing more than this guy advertised. The conduits are very easy to trim to length -- just cut the conduit with anything halfway sharp, take one end off, pull the wires back, and put it back together. I used the system with my mini split system, and it worked well.
For me to be able to run everything in my RV, I had to connect it to my workshop. To make a junction box outside my shop I had to install a breakers and create a junction box. On Amazon I discovered the outside junction box, and below it there was a "sometimes people buy this" post, but the Sealproof Power Whip assembly truly stood out! Definitely recommend this product! Everything I needed was included and I had a smooth time setting it up and using it! It is impossible to go wrong with this setup.